You're currently on:

Fluke 116 HVAC Digital True RMS Multimeter

Zoom Out
Zoom In

More Views

Fluke 116 HVAC Digital True RMS Multimeter

Model: JF116
UPC:
Chat with Texso Instruments
Call: 1 (760) 444-0032

Availability: In stock usually ships in 1 - 2 business days.

$209.95
Add Items to Cart

OR

Quick Overview

Fluke 116 True-RMS DMM has the functions HVAC/R installers and contractors need to troubleshoot HVAC equipment and flame sensor problems quickly. It features a built-in thermometer.

Product Description

  • Measure superheat and sub cooling: Measure key temperatures and pressures. Use the Fluke 116 with a Fluke velcro pipeclamp (included in kit) and the PV350 (optional) pressure module to determine superheat and sub cooling values. Detect problems like a clogged filter drier, undercharge, overcharge, faulty metering device or improper airflow, liquid line restriction or insufficient water flow.
  • Troubleshoot the defrost control on a heat pump: Check the temperature of the air coil or confirm when the defrost cycle starts and ends
  • Take temperature surveys: Test out compressor heads, oil sumps, evaporator coils and suction lines, plus discharge lines, condenser coils and the liquid line
  • Microamps measurement for testing flame sensors: When a furnace flame will not stay lit, use the Fluke 116 microamps measurement to troubleshoot the flame rod circuit.
  • LoZ reduces chance of false readings due to ghost voltage.
  • Features:
  • Large white LED backlight for excellent visibility in poorly lit areas
  • Min/Max/ Average to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • CAT III 600 V safety rated
  • General Specifications: Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of reading ] + [ counts ] )

  • Maximum voltage between any terminal and earth ground: 600 V
  • Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
  • Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
  • Display Digital: 6,000 counts, updates 4/sec
  • Bar graph 33 segments, updates 32/sec
  • Operating temperature -10 °C to + 50 °C
  • Storage temperature -40 °C to + 60 °C
  • Battery 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
  • Battery life 400 hours typical, N10140 without backlight


  • included:
  • TL75 Test Leads
  • Holster
  • User?s Manual
  • 9 V battery (installed)

Tags fluke 116, 116jf, fluke 116 dmm, fluke digital multimeter 116, jf116, fluke hvac 116 dmm

Additional Information

Specifications
Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 2.0% + 3
DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Auto volts
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 1.5 % + 2
Diode Test
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 μF / 0.01 μF
Range/Resolution: 100.0 μF / 0.1 μF
Range/Resolution: 9999 μF / 1 μF
Range/Resolution: 100 μF to 1000 μF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 μF
Accuracy: 5% + 20%
LoZ capacitance
Range: 1 nF to 500 μF
Accuracy: 10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution: -40 °C to 400 °C / 0.1 °C
Accuracy: 1% + 102
Range/Resolution: -40 °F to 752 °C / 0.2 °F
Accuracy: 1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution: 600.0 μA / 0.1 μA
Accuracy: 1.0% + 2
DC μamps
Range/Resolution: 600.0 μA / 0.1 μA
Accuracy: 1.0% + 2
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2

You may also be interested in the following product(s)

Fluke 117 Electricians Multimeter with Non-Contact Voltage

Fluke 117 Electricians Multimeter with Non-Contact Voltage
$212.95
     

Product Tags

Other people marked this product with these tags:
Add Your Tags:
Use spaces to separate tags. Use single quotes (') for phrases.
 

My Cart

You have no items in your shopping cart.

Compare Products

You have no items to compare.